CPR Training Simulator with Display System and Alarm code GLB-4001-B, developed for cardiopulmonary resuscitation practice, airway opening, chest compressions, artificial ventilation and carotid pulse assessment. It has light indicators and alarms for correct or incorrect compressions and ventilations, allows training in the 30:2 or 15:2 ratios, a rate of 100 to 120 compressions per minute and carotid pulse simulation via a manual pressure bulb. Ideal for classes in CPR, first aid, nursing, medicine, technical courses, clinical simulation and teaching laboratories.
Warranty
Equipment with warranty and original replacement parts
In-house support
Lemos & Andrade's own technical team
Delivery in Brazil and Paraguay
Logistics and installation across every Brazilian state and in Paraguay
Technical sheet
The CPR Training Simulator with Display and Alarm System, code GLB-4001-B, is designed for practical training of cardiopulmonary resuscitation, artificial ventilation, airway opening and carotid pulse assessment.
The model allows simulating a standard open airway and performing external chest compressions with monitoring by a display and alarm device. The system indicates correct and incorrect compressions by a light signal, and emits an alarm in the case of inadequate compression. It also allows assessing the intensity of the compression, considering the range of 2 to 3 cm as correct, and incorrect when below 2 cm or above 3 cm.
During artificial respiration, the simulator features a display and alarm device to indicate the ventilation volume. Ventilations below 150 ml, above 200 ml, too fast or excessive trigger a light indication and alarm, aiding the correct training of the technique. Adequate ventilation should occur between 150 and 200 ml.
The model allows training at a compression-to-artificial-respiration ratio of 30:2 for operation by one person or 15:2 for operation by two people, with an operating rate of at least 100 to 120 compressions per minute. It also allows simulating the carotid pulse by means of a manual pressure bulb, contributing to the training of circulatory response assessment.
Composed of:
Simulator for CPR training;
Airway with standard opening;
Chest for external compression;
Light display device;
Alarm system for incorrect compression;
Display system for artificial ventilation;
Alarm system for inadequate ventilation;
Pressure bulb for carotid pulse simulation.
Features and characteristics:
Allows simulation of a standard open airway;
Allows external chest compression training;
Has a light display for correct and incorrect compression;
Has an alarm for incorrect compression;
Allows assessment of compression intensity;
Indicates correct compression between 2 and 3 cm;
Indicates incorrect compression below 2 cm or above 3 cm;
Allows artificial respiration training;
Has display and alarm for ventilation volume;
Indicates ventilation below 150 ml or above 200 ml;
Indicates adequate ventilation between 150 and 200 ml;
Alerts in the case of ventilation that is too fast or excessive;
Allows training at the 30:2 ratio for one person;
Allows training at the 15:2 ratio for two people;
Allows an operating rate of 100 to 120 compressions per minute;
Allows operation in exercise mode;
Allows carotid pulse simulation by manual pressure bulb;
Indicated for CPR, first aid, nursing, medicine, technical health-area courses, clinical simulation and teaching laboratory classes.